Part Number Hot Search : 
TA7411AP 40T03GJ 64571 B65287 RF5604SB 1N5254 Z5234 0RNBSAC
Product Description
Full Text Search
 

To Download 2903262 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  https://www.phoenixcontact.com/us/products/2903262 09/06/2016???page? 1 ?/? 6 safety relays?-?psr-pip-24dc/mxf4/4x1/2x2/b?-?2903262 please be informed that the data shown in this pdf document is generated from our online catalog. please find the complete data in the user's documentation. our general terms of use for downloads are valid (http://phoenixcontact.com/download) multifunctional safety relay for emergency stop, safety doors, and light grid monitoring up to sil?3, cat. 4, pl?e, automatically or manually monitored activation, 4 n/o contacts, 3 safety functions, 2 shutdown levels, fixed push- in terminal blocks why buy this product ?up to cat.4/pl?e according to en?iso?13849-1, silcl?3 according to en?62061, sil?3 according to iec?61508 ?3 safety functions in one device ?low housing width of only 22.5mm ?no software configuration required ?also available with push-in connection key commercial data packing unit 1 stk weight per piece (excluding packing) 260.000 g custom tariff number 85371099 country of origin germany technical data note utilization restriction emc: class a product, see manufacturer's declaration in the download area dimensions width 22.5 mm height 106.4 mm depth 114.5 mm ambient conditions ambient temperature (operation) -20 c ... 45 c (see derating curve) osdd1 osdd2 11 12 13 14 s11 s21 i1 i2 i3 i4 i5 i6 light grid type 4 receiver transmitter emergencystop k5 k6 k7 k8 s4 s3 s5 k6 k5 k8 k7 n k5 k6 m k7 k8 m +24v dc osdd1 osdd2 11 12 13 14 l 13 23 43 53 a2a2 s34 s35 s36 s37 ( ) ( ) ( ) ( ) k1 k2 k3 k4 a1 s11 s21 i1 i2 i3 i4 i5 i6 14 24 32 44 54 62 psr-...-24dc/mxf4/4x1/2x2/b s0 s1 s2 (emergencystop) light grid type 4 receiver transmitter emergencystop k5 k6 k7 k8 s1 s0 s2 k6 k5 k8 k7 s0 s1 +24vdc ossd s2 13 23 43 53 a2a2 s34 s35 s36 s37 ( ) ( ) ( ) ( ) k1 k2 k1&k2 k3 k4 k3&k4 a1 s11 s21 i1 i2 i3 i4 i5 i6 14 24 32 44 54 62 relays outputs relays outputs logic reset 62 32 s11 s21 i1...i6 14 24 44 54 13 23 43 53 a1 a2 s36 s34 s37 s35 k 2k 4 k 1k 3 power24v dc reset k3/k4 reset k1/k2 k1/k2 k3/k4 monitoring output k3/k4 monitoring output k1/k2 output err i1/i2i3/i4 i5/i6 logic
https://www.phoenixcontact.com/us/products/2903262 09/06/2016???page? 2 ?/? 6 safety relays?-?psr-pip-24dc/mxf4/4x1/2x2/b?-?2903262 technical data ambient conditions ambient temperature (storage/transport) -25 c ... 85 c max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing) max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing) maximum altitude 2000 m (above sea level) input data nominal input voltage u n 24 v dc input voltage range in reference to u n 0.85 ... 1.1 typical input current at u n 125 ma (with actuated relays) 55 ma (two-channel 24 v/0 v + max. 200 ma control (message outputs 32/62) with non-actuated relays) current consumption typ. 5 ma (i max /i x inputs) 20 ma (in electric torque) voltage at input/start and feedback circuit 24 v -15?%; +10?% (first channel: 24?v; second channel: 0?v) typical response time 175 ms (monitored/manual start) 250 ms (automatic start) typ. starting time with u s 250 ms (when controlled via a1) typical release time 25 ms (when controlled via s11/s12 and s21/s22) 20 ms (when controlled via a1) concurrence input 1/2 recovery time 1 s (availability time after activation of sensor circuit: 100ms) status display 5 green leds maximum switching frequency 0.5 hz max. permissible overall conductor resistance 100 filter time max. 1.5 ms (test pulse duration; for all equivalent inputs) min. 7.5 ms (test pulse rate; for all equivalent inputs) output data contact type 4 enabling current paths 2 semiconductor alarm outputs contact material agcuni, +0,2 -0,4?m?au minimum switching voltage 10 v ac/dc maximum switching voltage 250 v ac/dc limiting continuous current 6 a (n/o contact) max. 100 ma (alarm output (24?v?dc)) inrush current, minimum 10 ma maximum inrush current 6 a sq. total current 72 a 2 ( th 2 = i 1 2 + i 2 2 + i 3 2 + i 4 2 (note derating)) osdd1 osdd2 11 12 13 14 s11 s21 i1 i2 i3 i4 i5 i6 light grid type 4 receiver transmitter emergencystop k5 k6 k7 k8 s4 s3 s5 k6 k5 k8 k7 n k5 k6 m k7 k8 m +24v dc osdd1 osdd2 11 12 13 14 l 13 23 43 53 a2a2 s34 s35 s36 s37 ( ) ( ) ( ) ( ) k1 k2 k3 k4 a1 s11 s21 i1 i2 i3 i4 i5 i6 14 24 32 44 54 62 psr-...-24dc/mxf4/4x1/2x2/b s0 s1 s2 (emergencystop) light grid type 4 receiver transmitter emergencystop k5 k6 k7 k8 s1 s0 s2 k6 k5 k8 k7 s0 s1 +24vdc ossd s2 13 23 43 53 a2a2 s34 s35 s36 s37 ( ) ( ) ( ) ( ) k1 k2 k1&k2 k3 k4 k3&k4 a1 s11 s21 i1 i2 i3 i4 i5 i6 14 24 32 44 54 62 relays outputs relays outputs logic reset 62 32 s11 s21 i1...i6 14 24 44 54 13 23 43 53 a1 a2 s36 s34 s37 s35 k 2k 4 k 1k 3 power24v dc reset k3/k4 reset k1/k2 k1/k2 k3/k4 monitoring output k3/k4 monitoring output k1/k2 output err i1/i2i3/i4 i5/i6 logic
https://www.phoenixcontact.com/us/products/2903262 09/06/2016???page? 3 ?/? 6 safety relays?-?psr-pip-24dc/mxf4/4x1/2x2/b?-?2903262 technical data output data interrupting rating (ohmic load) max. 1500 va (250 v ac, = 0 ms) 66 w (220 v dc, = 0 ms) 66 w (110 v dc, = 0 ms) 100 w (48 v dc, = 0 ms) 144 w (24 v dc, = 0 ms) maximum interrupting rating (inductive load) 48 w (24 v dc, = 40 ms) 43 w (48 v dc, = 40 ms) switching capacity min. 0.1 w output fuse 6 a gl/gg neozed (n/o contact) 4 a gl/gg neozed (for low-demand applications) general relay type electromechanical relay with forcibly guided contacts in accordance with en?50205 mechanical service life 10 x 10 6 cycles nominal operating mode 100% operating factor net weight 271.2 g mounting type din rail mounting assembly instructions see derating curve mounting position vertical or horizontal degree of protection ip20 min. degree of protection of inst. location ip54 control one and two channel housing color yellow connection data connection method push-in connection pluggable no conductor cross section solid min. 0.2 mm2 conductor cross section solid max. 2.5 mm2 conductor cross section flexible min. 0.2 mm2 conductor cross section flexible max. 2.5 mm2 conductor cross section awg min. 24 conductor cross section awg max. 12 stripping length 10 mm safety-related characteristic data stop category 0 safety integrity level (sil) 3 osdd1 osdd2 11 12 13 14 s11 s21 i1 i2 i3 i4 i5 i6 light grid type 4 receiver transmitter emergencystop k5 k6 k7 k8 s4 s3 s5 k6 k5 k8 k7 n k5 k6 m k7 k8 m +24v dc osdd1 osdd2 11 12 13 14 l 13 23 43 53 a2a2 s34 s35 s36 s37 ( ) ( ) ( ) ( ) k1 k2 k3 k4 a1 s11 s21 i1 i2 i3 i4 i5 i6 14 24 32 44 54 62 psr-...-24dc/mxf4/4x1/2x2/b s0 s1 s2 (emergencystop) light grid type 4 receiver transmitter emergencystop k5 k6 k7 k8 s1 s0 s2 k6 k5 k8 k7 s0 s1 +24vdc ossd s2 13 23 43 53 a2a2 s34 s35 s36 s37 ( ) ( ) ( ) ( ) k1 k2 k1&k2 k3 k4 k3&k4 a1 s11 s21 i1 i2 i3 i4 i5 i6 14 24 32 44 54 62 relays outputs relays outputs logic reset 62 32 s11 s21 i1...i6 14 24 44 54 13 23 43 53 a1 a2 s36 s34 s37 s35 k 2k 4 k 1k 3 power24v dc reset k3/k4 reset k1/k2 k1/k2 k3/k4 monitoring output k3/k4 monitoring output k1/k2 output err i1/i2i3/i4 i5/i6 logic
https://www.phoenixcontact.com/us/products/2903262 09/06/2016???page? 4 ?/? 6 safety relays?-?psr-pip-24dc/mxf4/4x1/2x2/b?-?2903262 technical data safety-related characteristic data 3 designation en iso 13849 performance level (pl) e (5?a?dc13; 3?a?ac15; 8760?cycles/year) category 4 safety integrity level claim limit (sil cl) 3 designation en?50156 safety integrity level (sil) 3 standards and regulations designation air clearances and creepage distances between the power circuits standards/regulations din en 50178/vde 0160 rated insulation voltage 250 v ac rated surge voltage/insulation 4 kv/basic isolation (safe isolation, reinforced insulation and 6 kv between input circuit, enabling current paths and safety circuit 1 (13/14, 23/24) and safety circuit 2 (43/44, 53/54).) degree of pollution 2 overvoltage category iii drawings circuit diagram circuit diagram osdd1 osdd2 11 12 13 14 s11 s21 i1 i2 i3 i4 i5 i6 light grid type 4 receiver transmitter emergencystop k5 k6 k7 k8 s4 s3 s5 k6 k5 k8 k7 n k5 k6 m k7 k8 m +24v dc osdd1 osdd2 11 12 13 14 l 13 23 43 53 a2a2 s34 s35 s36 s37 ( ) ( ) ( ) ( ) k1 k2 k3 k4 a1 s11 s21 i1 i2 i3 i4 i5 i6 14 24 32 44 54 62 psr-...-24dc/mxf4/4x1/2x2/b s0 s1 s2 (emergencystop) light grid type 4 receiver transmitter emergencystop k5 k6 k7 k8 s1 s0 s2 k6 k5 k8 k7 s0 s1 +24vdc ossd s2 13 23 43 53 a2a2 s34 s35 s36 s37 ( ) ( ) ( ) ( ) k1 k2 k1&k2 k3 k4 k3&k4 a1 s11 s21 i1 i2 i3 i4 i5 i6 14 24 32 44 54 62 relays outputs relays outputs logic reset 62 32 s11 s21 i1...i6 14 24 44 54 13 23 43 53 a1 a2 s36 s34 s37 s35 k 2k 4 k 1k 3 power24v dc reset k3/k4 reset k1/k2 k1/k2 k3/k4 monitoring output k3/k4 monitoring output k1/k2 output err i1/i2i3/i4 i5/i6 logic
https://www.phoenixcontact.com/us/products/2903262 09/06/2016???page? 5 ?/? 6 safety relays?-?psr-pip-24dc/mxf4/4x1/2x2/b?-?2903262 application drawing circuit diagram classifications ecl@ss ecl@ss 4.0 27371102 ecl@ss 4.1 27371102 ecl@ss 5.0 27371901 ecl@ss 5.1 27371901 ecl@ss 6.0 27371819 osdd1 osdd2 11 12 13 14 s11 s21 i1 i2 i3 i4 i5 i6 light grid type 4 receiver transmitter emergencystop k5 k6 k7 k8 s4 s3 s5 k6 k5 k8 k7 n k5 k6 m k7 k8 m +24v dc osdd1 osdd2 11 12 13 14 l 13 23 43 53 a2a2 s34 s35 s36 s37 ( ) ( ) ( ) ( ) k1 k2 k3 k4 a1 s11 s21 i1 i2 i3 i4 i5 i6 14 24 32 44 54 62 psr-...-24dc/mxf4/4x1/2x2/b s0 s1 s2 (emergencystop) light grid type 4 receiver transmitter emergencystop k5 k6 k7 k8 s1 s0 s2 k6 k5 k8 k7 s0 s1 +24vdc ossd s2 13 23 43 53 a2a2 s34 s35 s36 s37 ( ) ( ) ( ) ( ) k1 k2 k1&k2 k3 k4 k3&k4 a1 s11 s21 i1 i2 i3 i4 i5 i6 14 24 32 44 54 62 relays outputs relays outputs logic reset 62 32 s11 s21 i1...i6 14 24 44 54 13 23 43 53 a1 a2 s36 s34 s37 s35 k 2k 4 k 1k 3 power24v dc reset k3/k4 reset k1/k2 k1/k2 k3/k4 monitoring output k3/k4 monitoring output k1/k2 output err i1/i2i3/i4 i5/i6 logic
https://www.phoenixcontact.com/us/products/2903262 09/06/2016???page? 6 ?/? 6 safety relays?-?psr-pip-24dc/mxf4/4x1/2x2/b?-?2903262 classifications ecl@ss ecl@ss 7.0 27371819 ecl@ss 8.0 27371819 ecl@ss 9.0 27371819 etim etim 4.0 ec001449 etim 5.0 ec001449 approvals approvals approvals functional safety / ul listed / cul listed / eac / culus listed ex approvals approval details functional safety? ??01/205/5353.00/13 ul listed? ? http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/index.htm ?file e 140324 cul listed? ? http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/index.htm ?file e 140324 eac? ??7500651.22.01.00244 culus listed? ? phoenix contact 2016 ? - all rights reserved http://www.phoenixcontact.com osdd1 osdd2 11 12 13 14 s11 s21 i1 i2 i3 i4 i5 i6 light grid type 4 receiver transmitter emergencystop k5 k6 k7 k8 s4 s3 s5 k6 k5 k8 k7 n k5 k6 m k7 k8 m +24v dc osdd1 osdd2 11 12 13 14 l 13 23 43 53 a2a2 s34 s35 s36 s37 ( ) ( ) ( ) ( ) k1 k2 k3 k4 a1 s11 s21 i1 i2 i3 i4 i5 i6 14 24 32 44 54 62 psr-...-24dc/mxf4/4x1/2x2/b s0 s1 s2 (emergencystop) light grid type 4 receiver transmitter emergencystop k5 k6 k7 k8 s1 s0 s2 k6 k5 k8 k7 s0 s1 +24vdc ossd s2 13 23 43 53 a2a2 s34 s35 s36 s37 ( ) ( ) ( ) ( ) k1 k2 k1&k2 k3 k4 k3&k4 a1 s11 s21 i1 i2 i3 i4 i5 i6 14 24 32 44 54 62 relays outputs relays outputs logic reset 62 32 s11 s21 i1...i6 14 24 44 54 13 23 43 53 a1 a2 s36 s34 s37 s35 k 2k 4 k 1k 3 power24v dc reset k3/k4 reset k1/k2 k1/k2 k3/k4 monitoring output k3/k4 monitoring output k1/k2 output err i1/i2i3/i4 i5/i6 logic


▲Up To Search▲   

 
Price & Availability of 2903262

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X